CVE-2024-2854mediumCWE-78

CVE-2024-2854: medium-severity vulnerability in Tenda AC18

Tenda AC18 setsambacfg formSetSambaConf os command injection

Published · Updated

E-mail alert when it lands in KEV, gets a public PoC or its score goes up.

13Vexday Risk Score

No sign of exploitation. No public exploitation artifact known so far.

ssvc Trackcvss 6.3epss 3.9%
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Affected products
Tenda · AC18