CVE-2024-52067: medium-severity vulnerability in Apache NiFi
Apache NiFi: Potential Insertion of Sensitive Parameter Values in Debug Log
Published
E-mail alert when it lands in KEV, gets a public PoC or its score goes up.
13Vexday Risk Score
No sign of exploitation. No public exploitation artifact known so far.
ssvc Trackcvss 6.9epss 0.7%
Apache NiFi 1.16.0 through 1.28.0 and 2.0.0-M1 through 2.0.0-M4 include optional debug logging of Parameter Context values during the flow synchronization process. An authorized administrator with access to change logging levels could enable debug logging for framework flow synchronization, causing the application to write Parameter names and values to the application log. Parameter Context values may contain sensitive information depending on application flow configuration. Deployments of Apache NiFi with the default Logback configuration do not log Parameter Context values. Upgrading to Apache NiFi 2.0.0 or 1.28.1 is the recommendation mitigation, eliminating Parameter value logging from the flow synchronization process regardless of the Logback configuration.
CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:N/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N/AU:Y/R:U/V:D/RE:L/U:Green
Affected products
Apache Software Foundation · Apache NiFiRelated CVEs — Apache NiFi
In the same product, most dangerous first.
CVE-2023-34468HIGHApache NiFi: Potential Code Injection with Database Services using H2EPSS 61.9%CVE-2024-37389MEDIUMApache NiFi: Improper Neutralization of Input in Parameter Context DescriptionEPSS 24.0%CVE-2017-15697—CVE-2017-15697EPSS 4.8%CVE-2018-1309—CVE-2018-1309EPSS 4.4%CVE-2020-1928—CVE-2020-1928EPSS 4.0%CVE-2017-5636—CVE-2017-5636EPSS 3.6%