CVE-2024-54017
CVE-2024-54017
In short
SIPROTEC 5 protective relay devices use weak random number generation for security functions, making it easier for attackers to predict or forge security credentials. This affects the integrity and confidentiality of communications in critical power system infrastructure.
Technical detail
The vulnerability stems from insufficient entropy in random number generation (CWE-334) implemented across multiple SIPROTEC 5 relay models and firmware versions. An attacker with network access to the device can potentially predict cryptographic values or forge authentication tokens, compromising the confidentiality and integrity of management communications.
Summary generated and translated by AI from the official description.
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). Affected devices do not use sufficiently random values to create session identifiers. This could allow an unauthenticated remote attacker to brute force a session identifier and gain read access to limited information from the web server without authorization.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
Affected products
Siemens · SIPROTEC 5 6MD84 (CP300)Siemens · SIPROTEC 5 6MD85 (CP200)Siemens · SIPROTEC 5 6MD85 (CP300)Siemens · SIPROTEC 5 6MD86 (CP200)Siemens · SIPROTEC 5 6MD86 (CP300)Siemens · SIPROTEC 5 6MD89 (CP300)Siemens · SIPROTEC 5 6MU85 (CP300)Siemens · SIPROTEC 5 7KE85 (CP200)Siemens · SIPROTEC 5 7KE85 (CP300)Siemens · SIPROTEC 5 7SA82 (CP100)Siemens · SIPROTEC 5 7SA82 (CP150)Siemens · SIPROTEC 5 7SA84 (CP200)Siemens · SIPROTEC 5 7SA86 (CP200)Siemens · SIPROTEC 5 7SA86 (CP300)Siemens · SIPROTEC 5 7SA87 (CP200)Siemens · SIPROTEC 5 7SA87 (CP300)Siemens · SIPROTEC 5 7SD82 (CP100)Siemens · SIPROTEC 5 7SD82 (CP150)Siemens · SIPROTEC 5 7SD84 (CP200)Siemens · SIPROTEC 5 7SD86 (CP200)Siemens · SIPROTEC 5 7SD86 (CP300)Siemens · SIPROTEC 5 7SD87 (CP200)Siemens · SIPROTEC 5 7SD87 (CP300)Siemens · SIPROTEC 5 7SJ81 (CP100)Siemens · SIPROTEC 5 7SJ81 (CP150)Siemens · SIPROTEC 5 7SJ82 (CP100)Siemens · SIPROTEC 5 7SJ82 (CP150)Siemens · SIPROTEC 5 7SJ85 (CP200)Siemens · SIPROTEC 5 7SJ85 (CP300)Siemens · SIPROTEC 5 7SJ86 (CP200)Siemens · SIPROTEC 5 7SJ86 (CP300)Siemens · SIPROTEC 5 7SK82 (CP100)Siemens · SIPROTEC 5 7SK82 (CP150)Siemens · SIPROTEC 5 7SK85 (CP200)Siemens · SIPROTEC 5 7SK85 (CP300)Siemens · SIPROTEC 5 7SL82 (CP100)Siemens · SIPROTEC 5 7SL82 (CP150)Siemens · SIPROTEC 5 7SL86 (CP200)Siemens · SIPROTEC 5 7SL86 (CP300)Siemens · SIPROTEC 5 7SL87 (CP200)Siemens · SIPROTEC 5 7SL87 (CP300)Siemens · SIPROTEC 5 7SS85 (CP200)Siemens · SIPROTEC 5 7SS85 (CP300)Siemens · SIPROTEC 5 7ST85 (CP200)Siemens · SIPROTEC 5 7ST85 (CP300)Siemens · SIPROTEC 5 7ST86 (CP300)Siemens · SIPROTEC 5 7SX82 (CP150)Siemens · SIPROTEC 5 7SX85 (CP300)Siemens · SIPROTEC 5 7SY82 (CP150)Siemens · SIPROTEC 5 7UM85 (CP300)Siemens · SIPROTEC 5 7UT82 (CP100)Siemens · SIPROTEC 5 7UT82 (CP150)Siemens · SIPROTEC 5 7UT85 (CP200)Siemens · SIPROTEC 5 7UT85 (CP300)Siemens · SIPROTEC 5 7UT86 (CP200)Siemens · SIPROTEC 5 7UT86 (CP300)Siemens · SIPROTEC 5 7UT87 (CP200)Siemens · SIPROTEC 5 7UT87 (CP300)Siemens · SIPROTEC 5 7VE85 (CP300)Siemens · SIPROTEC 5 7VK87 (CP200)Siemens · SIPROTEC 5 7VK87 (CP300)Siemens · SIPROTEC 5 7VU85 (CP300)Siemens · SIPROTEC 5 Compact 7SX800 (CP050)Want to know if your infrastructure is exposed to this?