CVE-2026-115793highCWE-772

CVE-2026-115793: high-severity vulnerability in RT-Labs P-Net

Resource exhaustion from RPC sessions kept for requests to unknown interface

Published

E-mail alert when it lands in KEV, gets a public PoC or its score goes up.

21Vexday Risk Score

No sign of exploitation. No public exploitation artifact known so far.

ssvc Trackcvss 8.7epss 0.4%
P-Net before 1.0.3 does not release the RPC session allocated for an RPC request that names an unknown interface or object UUID, and does not start a timeout for it. Repeated requests with different activity UUIDs exhaust the available sessions. Once they are exhausted the device no longer answers new RPC requests, including Endpoint Mapper Lookup and Connect, until it is restarted. A remote unauthenticated attacker can use this to cause a denial of service.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Affected products
RT-Labs · P-Net