CVE-2026-22552: critical vulnerability in epower.ie
ePower epower.ie Missing Authentication for Critical Function
Published · Updated
E-mail alert when it lands in KEV, gets a public PoC or its score goes up.
28Vexday Risk Score
No sign of exploitation. No public exploitation artifact known so far.
ssvc Trackcvss 9.3epss 1.0%
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N
Affected products
ePower · epower.ieRelated CVEs — epower.ie
In the same product, most dangerous first.