CVE-2026-58115: critical vulnerability in Siemens SIMATIC IoT2050 Advanced…
Published · Updated
E-mail alert when it lands in KEV, gets a public PoC or its score goes up.
70Vexday Risk Score
Prioritize patching. It exploitation observed by VulnCheck and has a public proof of concept.
ssvc Actcvss 10epss 0.9%
from disclosure to weapon84 days
Published on NVDAug 11
1st PoC+84d
VulnCheck+80d
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.
This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Affected products
Siemens · SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)Siemens · SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)Siemens · SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)Siemens · SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)public PoCs found — 3
githubgithub.com/foxcornlab/node-red-scanner★ 0githubgithub.com/al4n4n/CVE-2026-58115★ 0vulncheckvulncheck.com/xdb/e1441057027dunverified⚠ Public resources, to assess the exposure of systems you control or are authorized to test. Test only with authorization.