CVE-2026-61884criticalCWE-306

CVE-2026-61884: critical vulnerability in Tycon Systems TPDIN-Monitor-WEB2

Tycon Systems TPDIN-Monitor-WEB2 Missing Authentication for Critical Function

Published · Updated

E-mail alert when it lands in KEV, gets a public PoC or its score goes up.

28Vexday Risk Score

No sign of exploitation. No public exploitation artifact known so far.

ssvc Trackcvss 9.3epss 0.6%
The Tycon Systems TPDIN-Monitor-WEB2 ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which could allow disruption of connected infrastructure or physical damage to equipment.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Related CVEs — Tycon Systems TPDIN-Monitor-WEB2

In the same product, most dangerous first.