← back
CVE-2026-80711

power: supply: max17040: handle missing status supplier

3Vexday Risk Score

No sign of exploitation. No public exploitation artifact known so far.

ssvc Trackepss 0.2%
exploitation probability
0.2%top 90% of all CVEs
observed exploitation
nono source reports it
In the Linux kernel, the following vulnerability has been resolved: power: supply: max17040: handle missing status supplier MAX17040 does not report charger state itself, so the driver forwards POWER_SUPPLY_PROP_STATUS to a supplier power supply. If no supplier is registered, power_supply_get_property_from_supplier() returns -ENODEV and leaves the output value untouched. max17040_get_property() currently ignores that error and returns success, so userspace can read an uninitialized status value from the battery power supply. This happens on systems that use the fuel gauge without a charger supplier relationship in firmware. Return POWER_SUPPLY_STATUS_UNKNOWN when no supplier provides STATUS, and propagate other supplier lookup errors.
Affected products
Linux · Linux