Vulnerabilities in Contec Co., Ltd.

57 results
Vexday analysis

A Contec Co., Ltd. apresenta 24 vulnerabilidades catalogadas, com apenas 1 crítica, mas nenhuma sob exploração ativa no momento. A fraqueza predominante é injeção de comando (CWE-78), padrão que requer atenção em processos de validação de entrada. A ausência de publicações recentes sugere um cenário de risco estável, sem novos vetores de ataque identificados nos últimos 90 dias.

CVE-2022-44456CRITICALCONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server wEPSS 69.9%CVE-2023-28651MEDIUMCross-site scripting vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. If a user who can access the affected produEPSS 62.4%CVE-2021-20660—Cross-site scripting vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to inject an arbitrary script via uEPSS 47.2%CVE-2023-29154HIGHSQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product witEPSS 41.4%CVE-2021-20658—SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to execute arbitrary OS commands with the web server privilege via unspecEPSS 3.7%CVE-2021-20657—Improper access control vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain and/or aEPSS 2.8%CVE-2021-20661—Directory traversal vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows authenticated attackers to delete arbitrary fileEPSS 2.5%CVE-2021-20659—SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to upload arbitrary files via unspecified vectors. If the fEPSS 2.1%CVE-2021-20662—Missing authentication for critical function in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to alter the setting infoEPSS 2.1%CVE-2023-27521HIGHOS command injection vulnerability in the mail setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F vEPSS 1.9%CVE-2023-27514HIGHOS command injection vulnerability in the download page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versiEPSS 1.9%CVE-2023-22373MEDIUMCross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an aEPSS 1.9%CVE-2026-82774HIGHImproper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in CONPROSYS M2M Gateway Series and EPSS 1.9%CVE-2026-82777HIGHImproper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in CONPROSYS PAC Series. If this vulEPSS 1.9%CVE-2026-82766HIGHImproper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SGA1000. If this vulnerability isEPSS 1.9%CVE-2026-82762HIGHImproper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec FX5000 series, FX4000 seriEPSS 1.9%CVE-2026-82794HIGHSolarView Compact contains an OS command Injection vulnerability in in Schedule Settings. If this vulnerability is exploited, an arbitrary OEPSS 1.9%CVE-2026-82791HIGHImproper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication WirEPSS 1.9%CVE-2023-27920MEDIUMImproper access control vulnerability in the system date/time setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and EPSS 1.8%CVE-2023-27518HIGHBuffer overflow vulnerability in the multiple setting pages of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F vEPSS 1.5%