CVE-2026-131196highCWE-476

CVE-2026-131196: fallo de gravedad alta en Splunk Enterprise

Denial of Service (DoS) through Splunk-to-Splunk Data Forwarding in Splunk Enterprise

Publicada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 7.5epss 0.3%
In Splunk Enterprise versions below 10.4.5, 10.2.9, 10.0.12, and 9.4.17, an unauthenticated user who can connect to a Splunk-to-Splunk (S2S) data forwarding receiver could cause the Splunk daemon to terminate unexpectedly. The unexpected termination interrupts data indexing and access to the management API and Splunk Web until the Splunk Enterprise process restarts. The vulnerability is possible because the S2S data forwarding receiver does not validate an optional field in forwarded event data, which results in a null pointer dereference when the field is missing. For more information see Intermediate data routing using universal and heavy forwarders (https://help.splunk.com/en/splunk-enterprise/get-started/splunk-validated-architectures/getting-data-in-forwarding-and-preprocessing/intermediate-data-routing-using-universal-and-heavy-forwarders) in the Splunk documentation.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Productos afectados
Splunk · Splunk Enterprise