CVE-2026-29127criticalCWE-269

CVE-2026-29127: fallo crítico en International Datacasting Corporation SFX2100…

Incorrect Permission Assignment(777) on `monitor` Users Home Directory Containing SUID Root Binaries in IDC SFX2100

Publicada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

28Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 9.2epss 0.2%
The IDC SFX2100 Satellite Receiver sets overly permissive file system permissions on the monitor user's home directory. The directory is configured with permissions 0777, granting read, write, and execute access to all local users on the system, which may cause local privilege escalation depending on conditions of the system due to the presence of highly privileged processes and binaries residing within the affected directory.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N