CVE-2026-29127criticalCWE-269

Incorrect Permission Assignment(777) on `monitor` Users Home Directory Containing SUID Root Binaries in IDC SFX2100

28Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 9.2epss 0.2%
probabilidade de exploração
0.2%top 93% das CVEs
exploração observada
nãonenhuma fonte reporta
The IDC SFX2100 Satellite Receiver sets overly permissive file system permissions on the monitor user's home directory. The directory is configured with permissions 0777, granting read, write, and execute access to all local users on the system, which may cause local privilege escalation depending on conditions of the system due to the presence of highly privileged processes and binaries residing within the affected directory.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N