CVE-2026-29122: falha de alta gravidade em International Datacasting Corporation SFX2100…
`/bin/date` Binary given SETUID Permissions on IDC SFX2100 Leading to Potential LPE
Publicada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 8.3epss 0.2%
International Data Casting (IDC) SFX2100 satellite receiver comes with the `/bin/date` utility installed with the setuid bit set. This configuration grants elevated privileges to any local user who can execute the binary. A local actor is able to use the GTFObins resource to preform privileged file reads as the root user on the local file system. This allows an actor to be able to read any root read-only files, such as the /etc/shadow file or other configuration/secrets carrier files.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:P
Produtos afetados
International Datacasting Corporation · SFX2100 Satellite ReceiverCVEs relacionadas — International Datacasting Corporation SFX2100…
No mesmo produto, das mais perigosas para as menos.
CVE-2026-29128HIGHIDC SFX2100 Satellite Receiver bgpd/ospfd/ripd/zebra Config Credential Disclosure via World-Readable FilesEPSS 0.3%CVE-2026-29127CRITICALIncorrect Permission Assignment(777) on `monitor` Users Home Directory Containing SUID Root Binaries in IDC SFX2100EPSS 0.2%CVE-2026-29121HIGH`/sbin/ip` Binary given SETUID Permissions on IDC SFX2100 Leading to Potential LPEEPSS 0.2%CVE-2026-29126HIGHWorld-Writable, Root Owned/Run `/etc/udhcpc/default.script` in IDC SFX2100 Satellite Receiver Leads To Potential LPEEPSS 0.2%CVE-2026-29123HIGHMultiple SUID Root Binaries in `xd` User Home Directory Leading to Potential Local Privilege EscalationEPSS 0.1%CVE-2026-29124HIGHMultiple SUID Root Binaries in `monitor` User Home Directory Leading to Potential Local Privilege EscalationEPSS 0.1%