CVE-2026-46086: falha em Linux
net: bridge: use a stable FDB dst snapshot in RCU readers
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
3Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackepss 0.1%
In the Linux kernel, the following vulnerability has been resolved:
net: bridge: use a stable FDB dst snapshot in RCU readers
Local FDB entries can be rewritten in place by `fdb_delete_local()`, which
updates `f->dst` to another port or to `NULL` while keeping the entry
alive. Several bridge RCU readers inspect `f->dst`, including
`br_fdb_fillbuf()` through the `brforward_read()` sysfs path.
These readers currently load `f->dst` multiple times and can therefore
observe inconsistent values across the check and later dereference.
In `br_fdb_fillbuf()`, this means a concurrent local-FDB update can change
`f->dst` after the NULL check and before the `port_no` dereference,
leading to a NULL-ptr-deref.
Fix this by taking a single `READ_ONCE()` snapshot of `f->dst` in each
affected RCU reader and using that snapshot for the rest of the access
sequence. Also publish the in-place `f->dst` updates in `fdb_delete_local()`
with `WRITE_ONCE()` so the readers and writer use matching access patterns.
Produtos afetados
Linux · LinuxCVEs relacionadas — Linux
No mesmo produto, das mais perigosas para as menos.
CVE-2026-31431HIGHcrypto: algif_aead - Revert to operating out-of-placeEPSS 98.1%KEVCVE-2026-46300HIGHnet: skbuff: preserve shared-frag marker during coalescingEPSS 17.2%KEVCVE-2024-53197HIGHALSA: usb-audio: Fix potential out-of-bound accesses for Extigy and Mbox devicesEPSS 4.1%KEVCVE-2024-53104HIGHmedia: uvcvideo: Skip parsing frames of type UVC_VS_UNDEFINED in uvc_parse_formatEPSS 3.4%KEVCVE-2025-39682CRITICALtls: fix handling of zero-length records on the rx_listEPSS 3.3%KEVCVE-2024-36971HIGHnet: fix __dst_negative_advice() raceEPSS 2.7%KEV
Referências
https://cert-portal.siemens.com/productcert/html/ssa-019113.htmlhttps://cert-portal.siemens.com/productcert/html/ssa-457936.htmlhttps://cert-portal.siemens.com/productcert/html/ssa-784472.htmlhttps://git.kernel.org/stable/c/0b9e4bbfb7c949151e3acd44ed4aa33614d2e110https://git.kernel.org/stable/c/1406c4e0ed1eaf8a29801ab1163d00fb7ee4359ahttps://git.kernel.org/stable/c/5424e678f9b304e148cf5dcc047cffc7a56a3bb5https://git.kernel.org/stable/c/81af4137a30c4c2dc694dea8cacb180bd66000efhttps://git.kernel.org/stable/c/9a2d9d4e657b23dc21f24cf139e3aeff0b61341fhttps://git.kernel.org/stable/c/a6ae4511c07b91f597e461406c6330f0d4ff810ehttps://git.kernel.org/stable/c/c502fa9f094cb03d1d1685c71e2105ab359bc2b8https://git.kernel.org/stable/c/df4601653201de21b487c3e7fffd464790cab808