CVE-2026-80754high

Input: synaptics-rmi4 - fix F55 transmitter electrode count typo

21Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 7.8epss 0.2%
probabilidade de exploração
0.2%top 94% das CVEs
exploração observada
nãonenhuma fonte reporta
In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos. This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses. Fix the typos by correctly assigning the TX electrode counts.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Produtos afetados
Linux · Linux