CVE-2026-98615

CVE-2026-98615: falha em Linux

eth: fbnic: Set AW_FLUSH_MODE alongside AW_FLUSH when flushing the mailbox

Publicada em · Atualizada em

3Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackepss 0.2%
probabilidade de exploração
0.2%top 94% das CVEs
exploração observada
nãonenhuma fonte reporta
In the Linux kernel, the following vulnerability has been resolved: eth: fbnic: Set AW_FLUSH_MODE alongside AW_FLUSH when flushing the mailbox When tearing down the FW mailbox Rx ring, fbnic_mbx_reset_desc_ring() writes AW_CFG with FLUSH set and everything else, BME included, cleared. Clearing BME halts the device's writes to the host but leaves the staged requests parked in the PUL write pipeline rather than draining them, so on the write path FLUSH alone never terminates the outstanding requests and the flush the firmware waits on never completes. Add the FLUSH_MODE definition and set both bits so the staged writes drain out of the pipeline on their own. BME stays cleared, so nothing lands on the host; it is restored later in fbnic_mbx_init_desc_ring() when the ring is rebuilt, once the outstanding writes are gone. The read path is unaffected. AR_CFG has no equivalent mode bit and AR_FLUSH terminates the outstanding reads by itself, so it is left as is. Both writes remain plain stores rather than read-modify-writes. That is deliberate: the matching write in fbnic_mbx_init_desc_ring() restores BME and the TLP attributes, and clears both flush bits as a side effect.
Produtos afetados
Linux · Linux