← volver
CVE-2025-54810highCWE-294

Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 8.6epss 0.2%
probabilidad de explotación
0.2%top 90% de las CVE
explotación observada
noninguna fuente lo reporta
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N