CVE-2025-54497: fallo de gravedad alta en Cognex In-Sight Explorer
Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource
Publicada el · Actualizada el
Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.
21Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackcvss 7.2epss 0.3%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a telnet-based service
on port 23 to allow management operations such as firmware upgrades and
device reboots, which require authentication. A user with protected
privileges can successfully invoke the SetSerialPort functionality to
modify relevant device properties (such as serial interface settings),
contradicting the security model proposed in the user manual.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N
Productos afectados
Cognex · In-Sight 2000 seriesCognex · In-Sight 7000 seriesCognex · In-Sight 8000 seriesCognex · In-Sight 9000 seriesCognex · In-Sight ExplorerCVEs relacionadas — Cognex In-Sight Explorer
En el mismo producto, de las más peligrosas a las menos.
CVE-2025-53969HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Client-Side Enforcement of Server-Side SecurityEPSS 0.4%CVE-2025-52873HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical ResourceEPSS 0.3%CVE-2025-54754HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Use of Hard-coded PasswordEPSS 0.3%CVE-2025-54810HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replayEPSS 0.2%CVE-2025-54818HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive InformationEPSS 0.1%CVE-2025-47698HIGHCVE-2025-47698EPSS 0.1%