← voltar
CVE-2025-54810highCWE-294

Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay

21Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 8.6epss 0.2%
probabilidade de exploração
0.2%top 90% das CVEs
exploração observada
nãonenhuma fonte reporta
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N