CVE-2025-40944: falha de alta gravidade em Siemens SIMATIC ET 200AL IM 157-1 PN
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 8.7epss 0.4%
A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (All versions < V1.3), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (All versions < V6.0.1), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (All versions >= V4.2.0 < V4.2.5), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (All versions < V4.2.2), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (All versions), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (All versions < V6.0.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (All versions >= V4.2.0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (All versions < V6.0.0). Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state.
This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Produtos afetados
Siemens · SIMATIC ET 200AL IM 157-1 PNSiemens · SIMATIC ET 200MP IM 155-5 PN HFSiemens · SIMATIC ET 200SP IM 155-6 MF HFSiemens · SIMATIC ET 200SP IM 155-6 PN/2 HFSiemens · SIMATIC ET 200SP IM 155-6 PN/3 HFSiemens · SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)Siemens · SIMATIC ET 200SP IM 155-6 PN R1Siemens · SIMATIC PN/MF CouplerSiemens · SIMATIC PN/PN CouplerSiemens · SIPLUS ET 200MP IM 155-5 PN HFSiemens · SIPLUS ET 200MP IM 155-5 PN HF T1 RAILSiemens · SIPLUS ET 200SP IM 155-6 PN HFSiemens · SIPLUS ET 200SP IM 155-6 PN HF T1 RAILSiemens · SIPLUS ET 200SP IM 155-6 PN HF TX RAILSiemens · SIPLUS NET PN/PN CouplerCVEs relacionadas — Siemens SIMATIC ET 200AL IM 157-1 PN
No mesmo produto, das mais perigosas para as menos.