CVE-2025-54818highCWE-319

Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information

21Vexday Risk Score

No sign of exploitation. No public exploitation artifact known so far.

ssvc Trackcvss 8.6epss 0.1%
exploitation probability
0.1%top 96% of all CVEs
observed exploitation
nono source reports it
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N