CVE-2025-54818: falha de alta gravidade em Cognex In-Sight Explorer
Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 8.6epss 0.1%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a proprietary protocol on TCP port 1069 to perform management operations
such as modifying system properties. The user management functionality
handles sensitive data such as registered usernames and passwords over
an unencrypted channel, allowing an adjacent attacker to intercept valid
credentials to gain access to the device.
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Produtos afetados
Cognex · In-Sight 2000 seriesCognex · In-Sight 7000 seriesCognex · In-Sight 8000 seriesCognex · In-Sight 9000 seriesCognex · In-Sight ExplorerCVEs relacionadas — Cognex In-Sight Explorer
No mesmo produto, das mais perigosas para as menos.
CVE-2025-53969HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Client-Side Enforcement of Server-Side SecurityEPSS 0.4%CVE-2025-52873HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical ResourceEPSS 0.3%CVE-2025-54497HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical ResourceEPSS 0.3%CVE-2025-54754HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Use of Hard-coded PasswordEPSS 0.3%CVE-2025-54810HIGHCognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replayEPSS 0.2%CVE-2025-47698HIGHCVE-2025-47698EPSS 0.1%