CVE-2025-54497highCWE-732

CVE-2025-54497: high-severity vulnerability in Cognex In-Sight Explorer

Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource

Published · Updated

E-mail alert when it lands in KEV, gets a public PoC or its score goes up.

21Vexday Risk Score

No sign of exploitation. No public exploitation artifact known so far.

ssvc Trackcvss 7.2epss 0.3%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSerialPort functionality to modify relevant device properties (such as serial interface settings), contradicting the security model proposed in the user manual.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N