CVE-2025-54497highCWE-732

Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource

21Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 7.2epss 0.3%
probabilidade de exploração
0.3%top 76% das CVEs
exploração observada
nãonenhuma fonte reporta
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSerialPort functionality to modify relevant device properties (such as serial interface settings), contradicting the security model proposed in the user manual.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N