CVE-2025-54860mediumCWE-307

CVE-2025-54860: fallo de gravedad media en Cognex In-Sight Explorer

Cognex In-Sight Explorer and In-Sight Camera Firmware Improper Restriction of Excessive Authentication Attempts

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

13Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 6.9epss 0.1%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow management operations on the device such as firmware upgrades and device reboot requiring an authentication. A wrong management of login failures of the service allows a denial-of-service attack, leaving the telnet service into an unreachable state.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N