CVE-2025-54860mediumCWE-307

CVE-2025-54860: falha de média gravidade em Cognex In-Sight Explorer

Cognex In-Sight Explorer and In-Sight Camera Firmware Improper Restriction of Excessive Authentication Attempts

Publicada em · Atualizada em

Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.

13Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 6.9epss 0.1%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow management operations on the device such as firmware upgrades and device reboot requiring an authentication. A wrong management of login failures of the service allows a denial-of-service attack, leaving the telnet service into an unreachable state.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N